RZ/A1L Group, RZ/A1LU Group, RZ/A1LC Group
10.8.3

Operation in Case of Re-Setting Due to Error during Operation, etc.

If an error occurs during operation of this module, the module output should be cut by the system. Cutoff is performed by
switching the pin output to port output with the general I/O port and outputting the inverse of the active level. The pin
initialization procedures for re-setting due to an error during operation, etc., and the procedures for restarting in a
different mode after re-setting, are shown below.
This module has six operating modes, as stated above. There are thus 36 mode transition combinations, but some
transitions are not available with certain channel and mode combinations. Possible mode transition combinations are
shown in Table 10.57.
Table 10.57
Mode Transition Combinations
Before
Normal
Normal
(1)
PWM1
(7)
PWM2
(13)
PCM
(17)
CPWM
(21)
RPWM
(26)
[Legend]
Normal: Normal mode
PWM1:
PWM mode 1
PWM2:
PWM mode 2
PCM:
Phase counting modes 1 to 4
CPWM:
Complementary PWM mode
RPWM:
Reset-synchronized PWM mode
R01UH0437EJ0600 Rev.6.00
Jan 29, 2021
PWM1
PWM2
(2)
(3)
(8)
(9)
(14)
(15)
(18)
(19)
(22)
None
(27)
None
10. Multi-Function Timer Pulse Unit 2
After
PCM
CPWM
(4)
(5)
(10)
(11)
(16)
None
(20)
None
None
(23) (24)
None
(28)
RPWM
(6)
(12)
None
None
(25)
(29)
10-155