Ppp Timeout Restart-Timer; Ppp Timeout Max-Configure - Alcatel-Lucent OmniAccess 700 CLI Command Reference Manual

Release versions: 2.2; 2.2-r02; 2.3
Table of Contents

Advertisement

PPP TIMEOUT RESTART
ppp timeout restart-timer <1-30>
D
ESCRIPTION
This command is Interface Configuration mode. This command sets a timer for re-
transmission of LCP and NCP packets.
P
ARAMETERS
1-30
D
V
EFAULT
ALUE
The default restart-timer value is "3 seconds".
E
XAMPLE
ALU(config-if Serial0/0:0)# ppp timeout restart-timer 13
PPP TIMEOUT MAX
ppp timeout max-configure <1-30>
D
ESCRIPTION
This command is used in the Interface Configuration mode. This command sets
the maximum number of configure request packets (LCP or NCP) sent without
receiving a valid Ack/NaK/Reject, before assuming that the peer is unable to
respond.
P
ARAMETERS
1-30
D
V
EFAULT
ALUE
The default max-configure value is "10 seconds".
E
XAMPLE
ALU(config-if Serial0/0:0)# ppp timeout max-configure 15
OmniAccess 700 CLI Command Reference Guide
Beta
-
TIMER
Parameter
-
CONFIGURE
Parameter
Alcatel-Lucent
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
Description
The timer for retransmission (in seconds) of LCP
and NCP packets. The range varies from 1-30.
Description
Maximum number of configure request packets
(LCP or NCP) to be sent without receiving a
valid Ack/NaK/Reject, before assuming that the
peer is unable to respond.