HDLC DOWN
WHEN
hdlc down-when-looped
D
ESCRIPTION
Enter this command in the Interface Configuration mode. This command is used
to bring down the line protocol when loopback is detected on the interface.
P
ARAMETERS
None.
D
V
EFAULT
ALUE
By default, bringing down of line protocol when the detected loopback is disabled.
E
XAMPLE
ALU(config-if Serial0/0:0)# no hdlc down-when-looped
DEBUG HDLC ALL
debug hdlc all [detail-level <1-9>]
D
ESCRIPTION
Enter this command in the Super User mode or Configuration mode. This
command shows all the debug messages pertaining to HDLC functionality.
P
ARAMETERS
all
detail-level
1-9
D
V
EFAULT
ALUE
By default, debug is disabled.
E
XAMPLE
ALU(config)# debug hdlc all
OmniAccess 700 CLI Command Reference Guide
Beta
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
-
LOOPED
Parameter
Alcatel-Lucent
hdlc down-when-looped
Description
Displays all the debug messages
pertaining to HDLC functionality.
Displays detail level (default is 1).
Enable with specific detail level.
Beta