Synchronization - Alcatel-Lucent OmniAccess 700 CLI Command Reference Manual

Release versions: 2.2; 2.2-r02; 2.3
Table of Contents

Advertisement

Field
Up/Down
State/PfxRcd

SYNCHRONIZATION

synchronization
D
ESCRIPTION
Enter this command in the Address Family or Router Configuration mode. This
command is used to enable the synchronization between the BGP and IGP
system.
P
ARAMETERS
None.
D
EFAULT
Enabled.
E
XAMPLE
ALU(config-router bgp AS30)# synchronization
OmniAccess 700 CLI Command Reference Guide
Beta
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
The length of time that the BGP session has been in the
Established state, or the current state if it is not Established.
Current state of the BGP session/the number of prefixes the
router has received from a neighbor or peer group. When
the maximum number (as set by the
neighbor_maximum_prefix command) is reached, the string
"PfxRcd" appears in the entry, the neighbor is shut down,
and the connection is Idle.
An (Administrator) entry with Idle status indicates that the
connection has been shut down using the
neighbor_shutdown command.