RELAY KEEPALIVE
frame-relay keepalive <0-32767>
D
ESCRIPTION
Enter this command in the Interface Configuration mode. This command is used
to configure the LMI Keepalive interval. The LMI keepalive value should typically
be equal to the corresponding interval at the switch.
P
ARAMETERS
0-32767
D
V
EFAULT
ALUE
The default LMI keepalive value is 10.
E
XAMPLE
The following example sets the LMI keepalive interval to 12.
ALU(config-if Serial0/0:0)# frame-relay keepalive 12
-
FRAME
RELAY LMI
frame-relay lmi-type {ansi|q933a}
D
ESCRIPTION
This command sets the LMI type to either ANSI or Q933A.
P
ARAMETERS
ansi
q933a
D
V
EFAULT
ALUE
The default LMI type is auto-sense.
LMI Autosense is activated by default as the system acts as a DTE. The LMI
autosense will be activated when the physical interface is up and LMI type is not
configured on that interface.
E
XAMPLE
The following example sets the LMI to ansi standard.
ALU(config-if serial0/0:0)# frame-relay lmi-type ansi
OmniAccess 700 CLI Command Reference Guide
Beta
Parameter
-
TYPE
Parameter
Alcatel-Lucent
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
Description
LMI keep alive interval in the range 0 to 32767.
Description
American National Standards Institute T1.617
Annex D.
ITU-T Q.933 Annex A.

frame-relay keepalive