Left running head:
Chapter name (automatic)
Multilink Frame Relay
INTERFACE MLFR
interface mlfr <1-256>
D
ESCRIPTION
This command is entered in the Configuration mode. This command configures a
MLFR bundle interface that is identified by a user specified number.
P
ARAMETERS
1-256
D
V
EFAULT
ALUE
None.
E
XAMPLE
ALU(config)# interface mlfr 100
ALU(config-if mlfr100)#
MLFR ACK INTERVAL
mlfr ack-interval <1-10>
D
ESCRIPTION
This command is entered in the Interface Configuration mode. This command
configures the acknowledge interval.
P
ARAMETERS
1-10
D
V
EFAULT
ALUE
Default value is 4 seconds.
E
XAMPLE
ALU(config-if Serial0/0:0)# mlfr ack-interval 5
298
Beta
Parameter
Parameter
Alcatel-Lucent
Description
Bundle identification. This number can
vary from 1 - 256.
Description
Acknowledge interval in seconds. The
range of this interval is from 1 second to
10 seconds.