Linecode; Line-Termination - Alcatel-Lucent OmniAccess 700 CLI Command Reference Manual

Release versions: 2.2; 2.2-r02; 2.3
Table of Contents

Advertisement

Left running head:
Chapter name (automatic)
T1E1 Line Card

LINECODE

linecode {ami|hdb3}
D
ESCRIPTION
This command is entered in the controller configuration mode to set a linecode for
the E1 interface. The E1 service provider determines which line-code type, ami or
hdb3, is required for your E1 circuit.
P
ARAMETERS
ami
hdb3
D
V
EFAULT
ALUE
HDB3 line code is the default for E1 lines.
E
XAMPLE
ALU(config-controller E1)# linecode hdb3
-
LINE
TERMINATION

line-termination {75|120}

D
ESCRIPTION
This command is entered in the Controller Configuration mode to configure a line
impedance of 75 or 120.
P
ARAMETERS
75|120
D
V
EFAULT
ALUE
The default line-termination value is 120.
E
XAMPLE
ALU(config-controller E1)#line-termination 120
214
Beta
Parameter
Parameter
Alcatel-Lucent
Description
Type of linecode.
High-density bipolar 3 (HDB3) line-code
type. Valid for E1 controller only.
Description
The line impedance value: 75 or 120
ohms.