BGP GRACEFUL
bgp graceful-restart-timers <1-175> <1-100>
D
ESCRIPTION
Enter this command in the Address Family or Router Configuration mode. This
command enables the graceful restart capability.
P
ARAMETERS
Parameter
1-175
1-100
D
V
EFAULT
ALUE
Restart timer - 175 seconds.
State Route Keep timer - 100 seconds.
E
XAMPLE
ALU(config-router bgp AS30)# bgp graceful-restart-timer 100 150
-
BGP LOG
NEIGHBOR
bgp log-neighbor-changes
D
ESCRIPTION
Enter this command in the Address Family or Router Configuration mode. This
command enables logging of messages when a BGP neighbor goes up or down
or resets.
P
ARAMETERS
None.
D
V
EFAULT
ALUE
Logging is disabled.
E
XAMPLE
ALU(config-router AS30)# bgp log-neighbor-changes
-
BGP ROUTER
ID
bgp router-id <ip-address>
OmniAccess 700 CLI Command Reference Guide
Beta
-
RESTART
TIMERS
Specifies the restart timer (in seconds).
Specifies the stale route keep timer (in seconds).
-
CHANGES
Alcatel-Lucent
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
Description
bgp graceful-restart-timers
413
Beta