2. In the above example, the channel-group command is shown only with a
value of '0'. The following example uses value in the range of 0-23:
To configure multiple channel groups with absolute values of timeslots:
ALU(config-controller T1)#channel-group 0 timeslots 1
ALU(config-controller T1)#channel-group 1 timeslots 2
To configure multiple channel groups with contiguous values of timeslots:
ALU(config-controller T1)#channel-group 3 timeslots 10-13
To configure multiple channel groups with non-contiguous values of timeslots:
ALU(config-controller T1)#channel-group 2 timeslots 3,6,9

CLOCKSOURCE

clocksource {internal|line}
D
ESCRIPTION
This command is entered in the controller configuration mode to set clocksource
for T1 interface. The keyword "clocksource" is used to transmit clock signals.
P
ARAMETERS
internal
line
D
V
EFAULT
ALUE
Default clocksource is internal.
E
XAMPLE
The following example configures the T1 clocksource for line:
ALU(config-controller T1)# clocksource line
OmniAccess 700 CLI Command Reference Guide
Beta
Parameter
The controller synchronizes itself to the internal
(system) clock.
The controller recovers external clock from the
line and provides the recovered clock to the
internal (system) clock generator.
Alcatel-Lucent
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
Description
clocksource
225