Measured TX Line
Frequency
Measured TX Line
Frequency Offset
OTN Overhead
OTN Transmit - OTN OH (Overhead)
TX Clock Loss Threshold, then the TX Clock Loss alarm
begins to accumulate.
Valid range is from 0 to +/- 300 ppm, in increments of 0.1
ppm, where 0 ppm is disabled. The default value is +/- 50
ppm.
This threshold alarm is only supported when the
Reference
is configured for Recovered.
This setting and the associated alarm are disabled when
the TX Clock Reference is set to Internal or
For the MPM-100G and MPM-100AR cards, this setting is
supported on the MLD tab.
The measured TX line frequency for the currently configured
interface (based on the selected reference clock) is
displayed.
When the
TX Clock Reference
Recovered, this measurement is derived from the external
recovered clock.
For the MPM-100G and MPM-100AR cards, this setting is
supported on the MLD tab.
Measures the Transmission Line Frequency Offset value in
Hz and PPM.
When the Clock Reference setting is set to Recovered,
this measurement indicates the deviation between the
system's Chassis clock and the Measured TX Line
Frequency.
For the MPM-100G and MPM-100AR cards, this setting is
supported on the MLD tab.