Inc. The software is protected by copyright and contains trade secrets of VeEX, Inc. or VeEX’s licensors. The software may be used or copied only in accordance with the terms of the agreement. It is against the law to copy the software onto any medium except as specifically allowed in the license or nondisclosure agreement.
Information in this document is subject to change without notice and does not represent a commitment on the part of VeEX Inc. The software and/or hardware described in this document are furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of the agreement.
Page 5 of 36 1. Introduction The FX80 power meter is designed to test passive optical networks (PON). It is used to simultaneously measure all optical signal levels between the Optical Line Terminal (OLT) and the Optical Network Unit/Terminal (ONU/ONT) on Gigabit B/E/GPON type networks. It can be connected onto the PON network at any available access point along the Optical Distribution Network (ODN).
Page 6
FX80 PON User Manual D07-00-115P RevA01 Page 6 of 36 1490, 1550, 1590, 1610, 1625, 1650 nm); • Visual Fault Locator (VFL) option; • Client USB software (LTSync) for data transfer to PC or cloud for future analysis and reporting.
• |Power|: Turn device ON/OFF. Press and hold the button for 3 sec. The display will initially show the VeEX logo, current date and time, and current mode of operation. • |MODE|: Select the mode of operation: PON Burst, PON CW, Read, optional PM1, optional VFL (default is PON Burst).
2.2.1. Optical Ports Figure 2. FX80 optical ports • OLT: Connect the FX80 to the fiber coming from the OLT to measure the downstream optical power levels in the PON network for 1490 nm (always present on active network) and 1550 nm (optional);...
OFF. When the FX80 is connected to AC power or an external power supply, the Plug icon ( ) will appear in the top left corner of the screen. If the device operates with the internal battery, the icon changes to Battery ( ).
2. With device OFF, press the red button and hold it for at least 15 seconds. |Power| The FX80 will reboot but you will need to reset the date and time (see Setting Date and Time). As a result of the reset, the threshold values and reference values will be lost. You need ...
4.2. PON Power Measurements For best results, we recommend you to wait for about 15 minutes after your FX80 is powered ON. This is especially advisable in environments with extreme temperature changes.
The FX80 is now ready for measurements. 4.2.2. Pass/Fail Thresholds In addition to measuring the downstream and upstream signal levels, the FX80 PON can also be configured to provide the user with Pass/Fail (P/F) notification for each wavelength. 4.2.2.1. Create User-Defined P/F Thresholds 1.
Page 13
FX80 PON User Manual D07-00-115P RevA01 Page 13 of 36 Figure 5. PON Burst mode 2. Press (P/F). The result is shown below: Figure 6. Setting Pass/Fail thresholds 3. Select the necessary wavelength Press the |Up| |Down| arrow button to to select the desired wavelength;...
|F1| (EXIT) to exit the Setting Pass/Fail thresholds mode. Your FX80 is now ready to start testing PON levels and compare PON optical power against the P/F thresholds settings. The P/F thresholds settings will remain active until it is changed.
Page 15
FX80 PON User Manual D07-00-115P RevA01 Page 15 of 36 Figure 7. Selecting the Default profile Table 1. ITU-T G.984-2 Standard Pass/Fail Thresholds 1.244 Gbs DS direction 1490nm OLT Launch Power 1490 ONT/ONU Receive Power Class A Class B Class C...
FX80 PON User Manual D07-00-115P RevA01 Page 16 of 36 622 Mbs DS direction 1310nm ONT/ONU Launch Power 1310 ONU Receive Power Class A Class B Class C Class A Class B Class C Min Avg Power (dBm) Max Avg Power...
Modes for Optical Power Measurements for details. 2. To test a PON network, you can insert the FX80 at one of above locations (see Figure typical passive optical network (PON) with possible points of measurement) along the PON network: OLT, Fiber Distribution Hub/Point (FDP) or ONU/ONT. You will need at least one extra patchcord to perform a test.
Page 18
FX80 PON User Manual D07-00-115P RevA01 Page 18 of 36 4. Once a good 1490 nm signal level is detected, connect the patchcord between the FX80 ONU/ONT right-side test port and the PON network element closest to the ONU/ONT to measure the 1310 nm upstream signal.
Page 19
FX80 PON User Manual D07-00-115P RevA01 Page 19 of 36 Figure 10. PON Burst mode measurement results as P/F thresholds To switch back to actual values for the same measurement, press the |F1| (P/F) button, which results in the interface shown below: Figure 11.
FX80 PON User Manual D07-00-115P RevA01 Page 20 of 36 4.2.4. Adding Comments to Measurement Results It may be necessary to add a note to your measurement results. To do that, when you are still in the measuring mode: 1. Press the |F3| (NOTE) button.
FX80 PON User Manual D07-00-115P RevA01 Page 21 of 36 current measurement results with the current note are saved in the device memory. If you do not save a note for your measurement results, the note from your previous ...
FX80 PON User Manual D07-00-115P RevA01 Page 22 of 36 Figure 14. Selecting a wavelenght for PM measurement Select a wavelength by pressing the |Up| |Down| buttons, then press the |Shift/Enter| button to confirm your choice. The new wavelength then appears in the top right corner of the display.
Page 23
FX80 PON User Manual D07-00-115P RevA01 Page 23 of 36 Figure 15. Selecting a reference option for PM measurement • REF FIX command: sets the current power value as the reference level. To do that, make sure the cursor is at REF FIX and press the |Shift/Enter| button.
• ZERO command: calibrates the ZERO level for the device. 4.4. Visual Fault Locator (VFL) Your FX80 can be equipped with a Visual Fault Locator (VFL). To test a fiber line for continuity, connect the fiber to the VFL port.
Page 25
FX80 PON User Manual D07-00-115P RevA01 Page 25 of 36 Figure 18. Starting VFL mode To start testing your fiber line for continuity, press the |F1| (ON) button. The result is shown below: Figure 19. Starting VFL testing, continuous light...
Page 26
FX80 PON User Manual D07-00-115P RevA01 Page 26 of 36 Figure 20. VFL testing, modulated light To go to another mode from the VFL mode, press the |MODE| button.
For your PC to work with the FX80 device, you need to install the FX40/45/80 USB driver: 1. Plug in the FX80 device to your PC via the supplied USB - microUSB cable. If you check your Windows Device Manager then, you see the FX80 item in the Other devices list.
Page 28
FX80 PON User Manual D07-00-115P RevA01 Page 28 of 36 Figure 21. Installing the driver for FX80 4. In the window which appears next select Browse my computer for driver software, then define the path where you previously saved the downloaded driver, and click [ Next ].
5.2. Transferring measurement results to PC To transfer measurement results to the PC: 1. Launch LTSync and connect your FX80 to the PC via the micro-USB cable provided. The resulting window is shown below, with the device and its serial number recognized...
Page 30
FX80 PON User Manual D07-00-115P RevA01 Page 30 of 36 Figure 23. FX80 is connected to PC in LTSync, its serial number is recognized by the program 2. To view the measurement results on the PC, click the [ Download ] button ( , see it, for...
Page 31
FX80 PON User Manual D07-00-115P RevA01 Page 31 of 36 Figure 24. Measurement results are presented as a table 3. To prepare your measurement results for a report, enter the pertinent information into the fields in the Attributes section (see, for example, the Figure above...
Figure Filtering measurement results by time). To erase all test results from the FX80 memory, go to the Hardware tab and click the [ Erase all memory ] button ( ). 6. Uploading Measurement Results to Fiberizer Cloud You can access your Fiberizer Cloud account within the LTSync program.
Service center. • Provide new software for the user to upgrade. The customer may elect to return the unit to VeEX Inc. along with the proof of purchase within thirty (30) days of the request by the customer, freight prepaid.
Page 34
FX80 PON User Manual D07-00-115P RevA01 Page 34 of 36 • Improper or inadequate maintenance by the customer; • Damage due to software installed by the customer on the unit without prior written authorization from VeEX Inc; • Unauthorized alteration or misuse;...
FX80 PON User Manual D07-00-115P RevA01 Page 35 of 36 Appendix A: Optical Specifications Table 2. PON Power Meter Calibrated wavelengths (nm) 1310/1490/1550 Number of test ports 2 (ONU, OLT) Continuous data measurement range (dBm) 1310 nm -40 to +10...
Page 36
FX80 PON User Manual D07-00-115P RevA01 Page 36 of 36 Table 3. Broadband Power Meter (Optonal) Wavelength range (nm) 850 to 1650 Calibrated wavelengths (nm) 1310/1490/1550/1625/1650 Power measurement range (dBm) Standard (PM1) -65 to +10 High (PM2) -50 to +25 Power measurement accuracy %, (dB) ±...