VeEX MPA User Manual page 219

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
OTU:BEI
ODU:BIP8
The following parameters are measured for the incoming errors:
Error count using an 11-digit format
Average error rate using an N.NNe-N format
Current error rate using an N.NNe-N format
Add/Drop Errors - When configured for a Multi-Channel or Multi-Level Add/Drop
mapping, the system can monitor and report errors on the incoming Add/Drop
ODU Mapping. The Add/Drop Errors function provides a detailed analysis of the
incoming error as described below.
The following OTN Add/Drop errors can be monitored:
For multi-level ODTU Add/Drop mappings, the following Add/Drop errors are
monitored for each ODU-j level.
A/D FRAME
A/D MFAS
A/D ODU:BIP8
A/D ODU:BEI
The following parameters are measured for the incoming errors:
Error count using an 11-digit format
Average error rate using an N.NNe-N format
Current error rate using an N.NNe-N format
Alarms - The system can monitor and report alarms and their duration on the
incoming OTN signal. The alarms are shown in duration of the alarm in seconds.
The following OTN alarms can be monitored:
LOS (Loss of Signal)
Power Hot - See
for details
219
Power Hot Alarm
BIT
A/D TCM1:BIP8 - Add/Drop
TCM6:BIP8
A/D TCM1:BEI - Add/Drop
TCM6:BEI
BIT
ODU:LCK
ODU:OCI