VeEX MPA User Manual page 33

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Getting Started
6. The cursor then appears after the current IP Gateway Addr.
a. To change the Gateway Address (Router Address), press the
Backspace key to delete the current Address, then type the new
Address followed by Enter to proceed to the next setting.
7. After the Gateway Address has been changed, a confirmation message appears
asking "Are you really sure?"
a. Press Y to Apply the new settings, followed by Enter.
b. Press N to Cancel the new settings, followed by Enter.
8. When the nat> command prompt reappears, the system will need to be turned
Off and back On.
a. Warning! Do not turn the chassis Power off without first deactivating MCH
and AMC cards.
9. Close the PuTTy connection as well as all remote software connections to the
MPA system such as the Remote Client GUI, VNC, SCPI or other software
connections to either the MCH or AMC Processor.
10. Follow the steps outlined in the Shutdown Procedure for turning the system's
power Off.
a. After the power to the chassis is turned off, then push both of the
Unlock/Extraction handles back in and turn the power switch back On.
b. Wait about 4 to 5 minutes for the system to fully reboot, and then verify
that you can Ping or login into the MCH module, via the newly configure IP
Address settings.
33

Hide quick links:

Advertisement

Table of Contents
loading