Pointer Action
Burst Count
Ms between Bursts
INC Pointer / DEC
Pointer (action
buttons)
Stop Sequence
(action button)
APS
Transmit APS
This is an Automatic Protection Switching (APS) function used to configure transmit
APS activity. APS is a feature that allows the LTE to switch to a backup line in case of
errors or failures on the main line. APS commands can be configured for either Linear-
increases the frequency justification rate.
This function is disabled by entering 0 for the frequency
offset.
Determines the type of Pointer activity that occurs when the
INC Pointer and DEC Pointer buttons are selected.
Single options - Inserts a single Pointer movement with
each selection of the INC Pointer or DEC Pointer button. The
Pointer value changes by one.
Increment/Decrement option -Determines the type of
Pointer activity that occurs when the INC Pointer and DEC
Pointer buttons are selected.
Continuous options - Inserts a continuous Pointer
movement with the selection of the INC Pointer or DEC
Pointer button. The movement continues until the Stop
Sequence button is selected.
This function allows you to determine the number of Pointer
location movements to occur when the INC Pointer or DEC
Pointer buttons are pressed. The Pointer burst count ranges
from 1 to 8.
Allows the user to set the number of Milliseconds between
bursts. Valid valued are 5.5 to 35000 milliseconds.
When a Single pointer action is selected, these will performs
a single pointer Increment or Decrement.
When a Continuous pointer action is selected, these will
begin the pointer Increment or Decrement Sequence.
This button becomes available when a Continuous pointer
sequence is running, this button will stop the pointer action
sequence.