MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
Trial Duration
Stream ID
Dest MAC
Address
Restore to RFC
Standard Setting
Enable/Disable
check boxes
Packet Sizes
BW Ceiling
BW Floor
547
Determines how long the test runs for each packet size. This
duration is used each time the test fails. Valid duration values
are 1-86400 seconds. The default value is 60 seconds.
Allows the user to select one of the four streams for the RFC
test.
Reflects the destination MAC address for the selected
Stream.
The
Dest MAC Address
Stream ID from the Traffic Stream Profile on the Conf screen.
For Fibre Channel rates, this is the
Returns frame sizes to default RFC test standards when user-
defined sizes have been set.
Allows the user to select the packet sizes that will be used for
the RFC tests.
Displays the packet sizes. Selecting a Packet Size button
allows the user to assign a user-defined frame size to the
packet.
Valid value ranges are 64 - 16000.
Sets the high-end of the bandwidth test range. The RFC test
will not exceed the setting. Valid values are 0.10 – 100.
IMPORTANT: The minimum delta between the ceiling and
floor setting is 1. For example, if the BW Floor is set to 9, then
the BW Ceiling must be set to 10, or greater.
Sets the low-end of the bandwidth test range. The RFC test
will not exceed the setting. Valid values are .01 – 99.
IMPORTANT: The minimum delta between the ceiling and
floor setting is 1. For example, if the BW Ceiling is set to 10,
then the BW Floor must be set to 9, or lower.