When the system is shipped from the factory, the SCM-210 controller card's
default IP Address is set to 192.168.0.10, with a Subnet Address of
255.255.255.0
The following methods can be used for changing the SCM-210's IP Address:
USB flash drive
Remote GUI Client
VNC)
AM4022 Processor and MCH Controller cards
This section describes how to configure the IP Address programmed on the MPA
system's
AM4022 processor
For MPA system containing an SCM-210 controller card, please refer to the section
above for configuring the IP Address.
The MPA's IP Address is configured on the AM4022 processor card and is used for all
Ethernet communication to the MPA system, such as Remote GUI, VNC and SCPI, via
the MCH's GbE port (as illustrated below).
Ethernet communication flows internally through the MCH's GbE port to the AM4022
processor. The two RJ-45 connectors on the AM4022 processor are not used.
(preferred method)
(must currently be connected by the Remote GUI client or
and the
MCH controller
Configuring the IP Address
card combination.