VeEX MPA User Manual page 651

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
(Specifically for Fibre Channel SAN testing on the Packet tab)
This is an RFC 2544 benchmark test that calculates your network's throughput rate. The
fastest throughput speed is indicated by the rate at which the transmission and
reception of the Ethernet test stream is accomplished without packet loss.
The following options appear on the Thru Put screen:
Option
Stream ID
Trial Duration
BW Ceiling
WWN Dest
Address
Dest Port
BW Floor
Accept Lost Rate
651
Description
Displays the ID number of the stream that will be used for the
RFC test.
The
Stream ID
is configured from the RFC Tests - Conf
screen.
Displays how long the test will run for each packet size. This
duration is used each time the test fails.
The
Trial Duration
screen.
Displays the setting for the high-end of the bandwidth test
range.
The
BW Ceiling
is configured from the RFC Tests - Conf
screen.
Displays the destination WWN address of the device that will
receive the RFC test.
The
WWN Dest Address
Stream ID from the Traffic Stream Profile on the Conf screen.
Displays the destination port that will receive the test signal.
The destination port configuration setting is not supported
on the MPA.
Displays the setting for the low-end of the bandwidth test
range.
The
BW Floor
is configured from the RFC Tests - Conf
screen.
Sets a packet loss rate threshold. The test fails if packet loss
exceeds this value. Valid values are 0-100%. The default is
is configured from the RFC Tests - Conf
is configured for the selected