VeEX MPA User Manual page 742

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
4. Select
Error Rate
dialog box.
5. Errors immediately start injecting into the packet stream when the error rate is
selected.
6. View various result statistics by selecting the
To stop error transmission select Error Rate and choose Off.
To insert a single error:
1. Select the Packet tab, select either GFP Bulk, GFP Framed Ethernet or GFP
Transparent mode.
Important: Traffic generation on at least one stream must
be enabled to inject errors.
2. Select Error / Alarm from the tabs along the left side of the Config Screen.
3. Select
Error Type
box.
Important: DO NOT set an Error Rate when inserting a
single error.
4. If you want to clear any previously collected data, select Restart from the
common function button at the bottom of the screen before inserting the error.
5. Select the Error Insert common function button at the bottom of the screen.
6. View various result statistics by selecting the
To insert an Alarm:
1. Select the Packet tab, select either GFP Bulk, GFP Framed Ethernet or GFP
Transparent mode.
Important: Traffic generation on at least one stream must
be enabled to inject errors.
2. Select Error Alarm from the tabs along the left side of the Config Screen.
3. Select
Alarm Generated
box.
and choose an error rate from the Select Error Rate to Insert
and choose an error type from the Select Error Type dialog
and choose an alarm type from the Select Alarm dialog
Results
function.
Results
function.
Packet Tab
742

Hide quick links:

Advertisement

Table of Contents
loading