VeEX MPA User Manual page 743

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
Important: Once an alarm is selected, then alarm will
continuously insert until turned off.
4. If you want to clear any previously collected data, select Restart from the
common function button at the bottom of the screen before inserting the error.
5. View various result statistics by selecting the
Viewing GFP Error and Alarm Results
(Specifically for GFP Mappings and GFP-F or GFP-T modes)
After
inserting error and alarms
the event and reports it. The Results screen provides different result reports.
To view error or alarm results:
1. From the Packet tab, select Results.
2. Select one of the following:
Scan
duration.
ERR
average and current rates.
ALARM
in the alarm condition.
Count
Strm Rslt
Event
Large LEDs
Recording in the Event Log
The Event Log is a table that displays events recorded by the unit. A scroll bar is
available, allowing you to scroll up and down to view an extended history.
To use the Event Log:
743
into a packet stream the receiving equipment detects
- Displays a list of errors and alarms along with their count and
- Displays a list of errors along with their count, errored seconds,
- Displays a list of alarms along with the number of seconds spent
- Displays Packet, VLAN, MPLS and Packet Size count statistics.
- Displays Stream ID specific statistics.
- Displays a summary of error alarm activity.
- Displays easy to read LEDs of error alarm activity.
Results
function.