VeEX MPA User Manual page 479

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
ES - Errored Seconds. Reports the duration of the incoming BIT errored blocks
per seconds, the percentage of errored seconds compared to the duration of
error free seconds, and the S1 and S2 percentage.
SES - Severely Errored Seconds. Reports the duration of Severely Errored
Seconds (SES), rate percentage, and the S1 and S2 percentage on the incoming
SDH signal. An SES is reported when the number of BIT errors per second
equals or exceeds 2,400 errors per second for HP mappings or 600 errors per
second for LP mappings, or when an LOS alarm, OOF alarm, LOF alarm, MS-
AIS alarm, AU-LOP alarm, AU-AIS alarm, HP-UNEQ alarm, TU-AIS alarm, TU-
LOP alarm, or TU-LOM alarm is present.
M.2101.1 Allocation. Select an allocation percentage from 0 to 100.
Duration. Set to 2 Hours, 1 Day, or 7 Days.
Status. Pass, Uncertain, or failure
Perf Monitor - M.2120 / M.2110
(Specifically for SDH testing)
The M.2120 / M.2110 screen provides a detailed breakdown for errors detected and
logged by the SDH protocol processor by using threshold error performance criteria with
respect to either a 15-minute (TR15) or 24-hour (TR24) evaluation period.
Error thresholds can be set directly from the M.2120 / M.2110
The following statistics appear on the M.2120 / M.2110
Statistic
Description
Event
Lists the error type and error.
TR15
Threshold Report 15-minute evaluation period. A TR is an error
performance report with respect to a 15-minute evaluation period.
There are one TR15 and one Reset TR15 (RTR15) for each
performance event.
The start and end time for the 15-minute evaluation window must
occur on the hour and at 15, 30, and 45 minutes with respect to the
elapsed time for each test. The TR15 evaluation period occurs as
soon as the 15-minute threshold is reached or exceeded. If the
479
screen.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents