MPA_e_manual_D07-00-129P_RevA00
Select the Stop common function button located at the bottom of the touch
screen.
To restart test activity and statistic reporting, select the Restart button.

Restarting a Test

The Restart common function button is used to initiate the following test activities:
Clears and resets error, alarm, and event activity counters, statistics, and LEDs
for the current protocol processor.
Restarts monitoring for error, alarm, or event activity that was stopped using the
Stop button.
Elapsed Time counter resets to 000 Days, 00 Hours, 00 Minutes, and 00
Seconds, and then begins to increment after the Restart finishes.
To restart a test or reset statistics:
Select the Restart common function button located at the bottom of the touch
screen. Configured testing on the current protocol processor is restarted.

Presets Function

The Presets function provides a quick and convenient way to set up the system for
operation. Using Presets involves selecting a starting protocol and its interface, and
then making an internal connection to another protocol, such as Add/Dropping from
OTN to a lower SONET/SDH mapping.
To set up a connection using the Presets function:
1. Select Presets from the Common Function Buttons row.
2. Select Interface. All line interfaces available for your unit appear.
3. Select an interface as a starting point.
4. Select Configuration. The protocols available for the selected interface appear.
5. Select a protocol to connect to the interface. If required, select the
Configuration button again to create additional connections.
Common Function Buttons
54