MPA_e_manual_D07-00-129P_RevA00
GUI System Tab
Important: The Processor / Mail Notify settings DO NOT persist after
the unit has been rebooted
9. After you have finished configuring the Email Alerts, the GUI must actively be
monitoring the specified protocol processor(s) for which the Email Alerts have
been configured, at all times.
Important: If the GUI is not monitoring the selected processor(s) at the
time a specified event occurs, an email will not be generated
For reliable email generation when multiple processors have been
configured to be monitored, you must select the All Tests Status window
located under the System tab. The All Test Status window is capable of
monitoring all processors at the same time, allowing emails to be
generated for any configured processor if a specified error or alarm event
occurs
If you have configured to monitor a single processor, then you may select
either the All Tests Status window, or any window under that processor's
tab
Note: A Remote GUI connection could be used for the sole purpose of
Email Alerts, to free up the local GUI (or other remote GUI's) for other
protocol testing purposes
Important: To activate the email notification function for multiple protocols you
must select the All Tests Status screen after the configurations are completed.
To terminate email alerts:
1. From the System tab, select User Preference. The User Preference screen
appears.
2. Select the Mail Interval button. The Select Duration of Test dialog box
appears.
3. Select OFF.
4. In the Processor/Mail Notify list box, select the protocol processor for which you
want to terminate the Email Alerts for and choose None from the Select
Error/Alarm Mail Notification window.