VeEX MPA User Manual page 311

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
SONET Error/Alarm - Error Insert Rate
This Error Insert Rate function sets the error rate for the selected error to insert. The
system starts transmitting errors after the insertion rate is selected.
For more information about inserting errors, see
Tasks section of this chapter.
The following Error Insert Rate options are available:
Option
Off
Maximum
1e - X
User Defined
SONET Error/Alarm - Alarm Generated
This Alarm Generated function determines the type of error transmitted by the system.
The purpose of generating an error or alarm is to stress the network element that is
receiving the error or alarm by testing if it can detect the incoming error/alarm and then
report error/alarm statistics or if it can perform the appropriate actions required.
For more information about generating alarms, see
Tasks section of this chapter.
Depending on the selected mapping, the following alarm types are available:
Alarm
None
311
Description
Turns error transmission off. This command effectively
disables the Error Insert Action button.
Generates errors at the maximum rate listed below.
X is a negative integer exponent, for example 1e-3. The X
may vary based on the type of error selected.
Allows the user to enter a custom error rate anywhere
between the Minimum and Maximum allowed rates.
Description
No alarms are generated. Turns alarms off.
Inserting Errors
in the SONET Specific
Insert Alarms
in the SONET Specific