OPU Frequency
Offset
Initial Laser Setting
ODU-j Mapping
Note: The ODU-j
Mapping function is
only available for
ODTU Add/Drop
multi-level
mappings.
The Line Frequency Offset can also be configured for Ramp
mode. Select the Ramp Frequency Offset Mode checkbox
to enable Ramp mode, and deselect the checkbox to disable
Ramp mode.
In Ramp mode, the line frequency offset will
continuously increment and decrement from one user-
defined Offset Peak to second user-defined Offset
Peak, each ranging from -300.0 to 300.0 PPM's.
A user-defined Step Size can be set (in PPM's), and a
user-defined Step Duration (in Seconds) can also be
configured.
The min/max frequency offset range is -150.0 to 150.0 for
Packet based mappings.
Use the keypad to enter the offset frequency parameters.
The Line Frequency Offset setting is only available when
the Clock Reference is set to Internal timing.
Sets the Optical Channel Payload Unit (OPU) frequency
offset in ppm.
The OPU Frequency Offset setting is only available for
ODTU Multi-Chan, ODTU Add/Drop, or SONET/SDH
Asynchronous mappings.
Controls whether the laser is on or off when the unit is turned
on.
Off. The unit's laser will be off when the unit is turned on.
On. The unit's laser will be on when the unit is turned on.
Restore Previous State. When the unit is turned on, the
laser will be on or off based on its previous setting before the
unit was turned off.
Configures the lowest ODU-j Add/Drop mapping structure to
be multiplexes into the ODTU Add/Drop multi-level mapping.
SDH Synchronous: The Optical Channel Payload
Unit (OPU) of the foreground ODU-j Mapping is
synchronized with the rest of the OTN frame, and the
payload data is defined by the configuration settings
OTN Tab