MPA_e_manual_D07-00-129P_RevA00
Config - Strms Pg 1 and Strms Pg 2
(Specifically for GFP-F or GFP-T testing on the Packet tab)
The Strms Pg 1 (Streams Page 1) and Strms Pg 2 (Streams Page 2) screens are used
for configuring and testing packet streams.
The Strms Pg 1 side tab is used to control Streams 1 through 16, and Strms Pg 2
controls Streams 17 through 32.
Important: When the processor is licensed for the Advanced Ethernet test option,
then up to 32 independent test streams can be configured and simultaneously
generated and tested, per port. Otherwise only 1 test stream can be generated and
tested, per port.
On/Off
Checkboxes (1-32)
packets sent and received
Enables packet generation for the specified Stream Id.
When enabled (on) the selected stream will begin
transmitting packet at the Rate specified in the
Profile
dialog box. By default, each stream is configured for
1.00% BW.
If the total configured bandwidth for all streams enabled
exceeds 100%, the processor will evenly scale back the
actual rates generated to achieve a maximum bandwidth of
exactly 100%.
Packet Tab
Traffic Stream