VeEX MPA User Manual page 444

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Expected LP
Signal Label
TIM Alarm
Reporting
Select one of the following values for the expected Lower
Order Path Signal:
The following options are available:
00 (Unequipped)
01 (Equipped)
02 (Asynchronous)
03 (Bit Synchronous)
04 (Byte Synchronous)
(05) ATM
06 (O.181 Test Signal Mapping)
07 (VC-AIS)
User Defined - Any 3-bit value 0h to 7h
This option is only available for C-2, C-12, and C-11
mappings.
Enables or Disables Trace Identifier Mismatch (TIM) alarm
reporting.
A Regenerator Section Trace Identifier Mismatch (RS-
TIM) alarm occurs when the incoming J0 trace does
not match the Expected J0 trace setting.
An Higher-order Path Trace Identifier Mismatch (HP-
TIM) alarm occurs when the incoming J1 trace does
not match the Expected J1 trace setting.
A TCM Trace Identifier Mismatch (HP-TC-TIM) alarm
occurs when the incoming TC trace does not match
the Expected TC Trace setting, and when TC
Error/Alarm Processing is enabled.
When Disabled, all TIM alarms are ignored.
SDH Tab
444