VeEX MPA User Manual page 687

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
TX PTI
TX UPI
TX Spare
TX CID
687
Allows the user to configure the Payload Type Identifier value. The
TX PTI can be set to:
000 - Client Data Frame
100 - Client Mgmt Frame
User Defined (range from 1 to 7, entered using a touch
screen keypad)
See
inserting LOCS and LOCCS alarms
PTI.
Allows the user to configure the User Payload Identifier value.
The TX UPI can be set to:
0x01 - Framed Eth
0x02 - Framed PPP
0x03 - Trans FC
0x04 - Trans FICON
0x05 - Trans ESCON
0x06 - Trans GbE
0x08 - MAPOS
0xFD - GFP 64/66B LAN
0xFE - GFP bulk fill
User Defined (range from 1 bit to 32 bits and is entered
using a touch screen keypad)
See
inserting LOCS and LOCCS alarms
UPI.
Allows the user to configure the Spare Field value, ranging 0 to
255 entered using a touch screen keypad.
Important: The EXI mode has to be set for Linear for this setting
to be enabled.
Sets the transmitted Channel ID value, ranging from 0 to 255, in
the Extension Header. The default value is 0.
Important: The EXI mode has to be set for Linear for this setting
to be enabled.
for their affect on the
for their affect on the