VeEX MPA User Manual page 242

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Interface
Granular accuracy per
Rate
frame
OTU4
0.001 ms (1.168 µs)
OTU3
0.003 ms (3.035 µs)
OTU3e1
0.003 ms (2.929 µs)
OTU3e2
0.003 ms (2.928 µs)
OTU2
0.012 ms (12 µs)
OTU1e
0.012 ms (12 µs)
OTU2e
0.012 ms (12 µs)
OTU1f
0.012 ms (12 µs)
OTU2f
0.012 ms (12 µs)
OTU1
0.049 ms (49 µs)
The Service Disruption
measurements (in ms).
A complete summary of Service Disruption measurements for all processors in the
unit can be viewed by selecting the System tab and choosing
OTN Test - RTD (Round-Trip Delay)
The round-trip delay function allows you to transmit a known frame into your network
and measure how long it takes for the frame to return to the unit.
Max number of Good Frames (Good
Time) allowed
16383 frames (19.130 ms)
16383 frames (49.722 ms)
16383 frames (47.990 ms)
16383 frames (47.977 ms)
16383 frames (199.732 ms)
16383 frames (193.588 ms)
16383 frames (192.777 ms)
16383 frames (189.794 ms)
16383 frames (188.997 ms)
16383 frames (802.302 ms)
Reports
include up to 200 of the most recent switch
OTN Tab
Service
Disruption.
242