VeEX MPA User Manual page 699

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
Ether Type
UDP Src port
UDP Dest port
Frame Size
Payload
699
configuration.
A two-octet field in an Ethernet frame, used to indicate which
protocol is encapsulated in the payload.
The following menu items are available:
Internet Protocol, Version 4 (IPv4) 0x0800 (* default
value)
Internet Protocol, Version 6 (IPv6) 0x086DD
MPLS 0x8847
User defined (0x0 to FFFF)
Selects a User Data Protocol source port number (0 to 65535).
Selects a User Data Protocol destination port number (0 to
65535)
Port 0 is an officially reserved port in TCP/IP networking, and
should not be used.
Sets the frame length in bytes. The frame size is entered as a
decimal value, entered using a keypad, ranging from 64 to
16000. The default value is 128 bytes.
Allows the user to select a test pattern to be transmitted in the
stream's payload.
Select one of the following patterns:
PRBS
9,
PRBS 9
Inv,
15
Inv,
PRBS
20,
PRBS 20
31,
PRBS 31
Inv, or a
PRBS
11,
PRBS 11
Inv,
Inv,
PRBS
23,
PRBS 23
User Defined
(32-bit value).
PRBS
15,
PRBS
Inv,
PRBS

Hide quick links: