VeEX MPA User Manual page 574

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
The following error types can be monitored:
Error Type
Code
Undersized
Invalid FCS
Invalid IP
Invalid UDP
Runts
The following error statistics are displayed:
Statistic
Error
Count
Errored Seconds
Average
Description
A Code error or Symbol error is detected in the line encoding
A frame whose length is < 64 bytes, with good FCS/CRC
checksum
An error in the Frame Check Sequence (CRC checksum),
and whose Frame length is ≥ 64 bytes
An error in the frame's IP Checksum
An error in the frame's UDP Checksum
A frame whose length is < 64 byte with an FCS error
Description
Displays the error type recognized and recorded by the unit.
Displays the number of errors using an 11-digit format.
Displays the number of errored seconds.
Displays the average error rate using an N.NNe-N format.
Packet Tab