VeEX MPA User Manual page 474

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
SES - Severely Errored Seconds. Reports the duration of Severely Errored
Seconds (SES), rate percentage, and objective percentage on the incoming SDH
signal. An SES is reported when the number of HP-REI errored blocks per
second equals or exceeds 2,400 errors per second, or when an HP-RDI alarm
is present.
G.826/G.828 Allocation - Select an allocation percentage from 0 to 100.
Status - Pass, Uncertain, or failure
G.826/G.828 button. Select the command button to toggle between G.826 and
G.828 error statistics.
M.2101.1 Near B3 Errors
ES - Errored Seconds. Reports the duration of the incoming B3 errored
blocks per seconds, the percentage of errored seconds compared to the
duration of error free seconds, and the S1 and S2 percentage.
SES - Severely Errored Seconds. Reports the duration of Severely
Errored Seconds (SES), rate percentage, and the S1 and S2 percentage
on the incoming SDH signal. An SES is reported when the number of B3
errored blocks per second equals or exceeds 2,400 errors per second,
or when an Out Of Frame (OOF) alarm, Loss of Frame (LOF) alarm, Loss
of Signal (LOS) alarm, MS-AIS alarm, AU-LOP alarm, AU-AIS alarm or
HP-UNEQ alarm is present.
M.2101.1 Allocation - Select an allocation percentage from 0 to 100.
Duration - Set to 2 Hours, 1 Day, or 7 Days.
Status - Pass, Uncertain, or failure
M.2101.1 Far HP-REI Errors
ES - Errored Seconds. Reports the duration of the incoming HP-REI
errored blocks per seconds, the percentage of errored seconds compared
to the duration of error free seconds, and the S1 and S2 percentage.
SES - Severely Errored Seconds. Reports the duration of Severely
Errored Seconds (SES), rate percentage, and the S1 and S2 percentage
on the incoming SDH signal. An SES is reported when the number of HP-
REI errored blocks per second equals or exceeds 2,400 errors per
second, or when an HP-RDI alarm is present.
M.2101.1 Allocation - Select an allocation percentage from 0 to 100.
Duration - Set to 2 Hours, 1 Day, or 7 Days.
SDH Tab