MPA_e_manual_D07-00-129P_RevA00
SER Activate
Threshold
SER Deactivate
Threshold
MLD Receive - Multi Lanes
The Receive Multi Lanes screen shows received Skew delay measurements for each of
the Physical lanes and Logical/FEC/PCS virtual lanes.
In the Multi Lane table the following columns are shown:
Physical Lane
Sets the number of Symbols for the SER Activate Threshold,
from 0 to 15 times the SER Degrade Interval's value, with a
maximum limit of 65535. (MPM-400G card only)
This value must be greater than the SER Deactivate
Threshold value, but cannot exceed 15 times the SER
Degrade Interval's value.
If the value entered does exceed 15 times the SER
Degrade Interval's value, then this setting will automatically
be adjusted to exactly 15 times the SER Degrade Interval's
current value.
If the value of this setting is set to 0 (which is Disabled),
then the FEC Degraded SER alarm feature is Disabled.
Sets the number of Symbols for the SER Deactivate
Threshold, from 0 to 65534. (MPM-400G card only)
The SER Deactivate Threshold value must be less than
the SER Activate Threshold value.
If the value entered is greater than the SER Activate
Threshold's value, then this setting will automatically be
adjusted to 1 Symbol less than the SER Activate Threshold's
current value.
If the value of this setting is set to 0 (which is Disabled),
then the FEC Degraded SER alarm feature is Disabled.
Displays the Physical Lane number.
MLD Tab