VeEX MPA User Manual page 214

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
OTN Receive - Capture
Use the Capture screen to capture 256 bytes of received overhead bytes, before/after a
triggered event occurs.
Function
Byte Select
Description
Select the overhead byte to be captured.
OTU:FAS OA1 1
OTU:FAS OA1 2
OTU:FAS OA1 3
OTU:FAS OA2 1
OTU:FAS OA2 2
OTU:FAS OA2 3
OTU:MFAS
OTU:SM TTI
OTU:SM BIP
OTU:SM BEI
OTU:GCC0 1
OTU:GCC0 2
OTU:RES 1
OTU:RES 2
ODU:TCM1 TTI
ODU:TCM2 TTI
ODU:TCM3 TTI
ODU:TCM4 TTI
ODU:TCM5 TTI
ODU:TCM3 BIP
ODU:PM BIP
ODU:TCM4 BIP
ODU:PM BEI
ODU:TCM5 BIP
ODU:EXP 1
ODU:TCM6 BIP
ODU:EXP 2
ODU:TCM1 BEI
ODU:GCC1 1
ODU:TCM2 BEI
ODU:GCC2 1
ODU:TCM3 BEI
ODU:GCC1 2
ODU:TCM4 BEI
ODU:GCC2 2
ODU:APS PCC
ODU:TCM5 BEI
1
ODU:APS PCC
ODU:TCM6 BEI
2
ODU:APS PCC
ODU:RES 1
3
ODU:APS PCC
ODU:RES 2
4
ODU:PM and
OPU:JC-1 (or
TCM
OPU:RES 5)
OPU:JC-2 (or
ODU:RES 4
OPU:RES 6)
OPU:JC-3 (or
ODU:RES 5
OPU:RES 7)
OPU:NJO (or
ODU:RES 6
OPU:RES 8)
ODU:RES 7
OPU:PSI
ODU:RES 8
OPU:RES 1
ODU:RES 9
OPU:RES 2
OTN Tab