The MLD tab allows you to configure and monitor the slice's optical power,
OTLC.n, FEC and Skew.
The OTN tab allows you to configure and monitor the slice's overhead and
traces, errors and alarms, Service Disruption and Round-Trip-Delay
measurements.
Service Disruption and RTD measurements can only be made from the OTUCn
group controlling slice (Slice #1).
For more information about OTUCn groups, see
For OTUCn example groups, see
OTUCn Examples
Depending on the configuration of an MPA unit, the OTUCn feature can support multiple
different configurations; including up to six (6) OTUC1's, three (3) OTUC2's, two (2)
OTUC3's, one (1) synchronized OTUC6, one (1) OTUC2 and one (1) OTUC4, as well
as multiple other OTUCn combinations.
Below are just a few examples of various OTUCn configurations, based on an MPA unit
with six (6)
MPM-100AR
As illustrated in the examples below, the size of the OTUCn group is based on the
number of slices (members) in the group. Hence, and OTUC2 has two slices, and
OTUC3 has three slices, etc.
Each OTUCn group also has a unique group identification number (#), based on the
Slot # of the group's controlling slice (Slice #1's Slot #).
OTUCn Examples
cards, and an
SCM-210
OTUCn Overview
controller card.
OTN Tab