VeEX MPA User Manual page 690

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
TX PTI
TX UPI
TX CID
RX Pattern
Allows the user to configure the Payload Type Identifier value. The
TX PTI can be set to:
000 - Client Data Frame
100 - Client Mgmt Frame
User Defined (range from 1 to 7, entered using a touch
screen keypad)
See
inserting LOCS and LOCCS alarms
PTI.
Allows the user to configure the User Payload Identifier value.
The TX UPI can be set to:
0x01 - Framed Eth
0x02 - Framed PPP
0x03 - Trans FC
0x04 - Trans FICON
0x05 - Trans ESCON
0x06 - Trans GbE
0x08 - MAPOS
0xFD - GFP 64/66B LAN
0xFE - GFP bulk fill
User Defined (range from 1 bit to 32 bits and is entered
using a touch screen keypad)
See
inserting LOCS and LOCCS alarms
UPI.
Sets the transmitted Channel ID value, ranging from 0 to 255, in
the Extension Header. The default value is 0.
Important: The EXI mode has to be set for Linear for this setting
to be enabled.
Selects the type of pattern that the unit expects to receive on the
incoming GFP frames. The payload can be set to:
PRBS 31
User Defined (range from 1 bit to 32 bits and is entered
using a touch screen keypad)
Packet Tab
for their affect on the
for their affect on the