MPA_e_manual_D07-00-129P_RevA00
Out of Frequency
Threshold
Trigger Out
SONET Receive - Set / Set 2
Use the Set 1, Set 2 and Set 3 screens to configure the SONET Receive parameters.
The following describes the functions that appear on the Set 2 screen, depending on the
card type and configuration.
Function
PLM Alarm
Reporting
Sets the threshold for which the Frequency Wide alarm
occurs. When the received Line Frequency Offset (in ppm)
exceeds the set threshold setting, the Frequency Wide alarm
will occur.
The threshold value is entered using an on-screen keypad,
and can range from 0 ppm to +/- 300.0 ppm in increments of
0.1 ppm. The default value is 0 ppm (Disabled).
Trigger Out is currently not supported.
Description
Enables or Disables Payload Label Mismatch alarm
reporting.
SONET Tab
322