VeEX MPA User Manual page 420

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
K2 Bits 6-8 (Linear Mode)
This function edits the 6th, 7th, and 8th bits of the K2 byte. These bits indicate if a FERF
or FEBE occurs at the line level. The current value displays in the User Setup column of
the APS Commands function.
Options
(000) Unused
(001) Unused
(010) Unused
(100) Unused
(100) Uni-direct
(101) Bi-direct
(110) MS-RDI /
RDI-L
(111) MS-AIS /
AIS-L
K1 Full Byte (Ring Mode)
This function configures the bit pattern of the K1 byte using either predefined or user
defined settings by individually setting the eight bits of the K1 byte using the touch
screen keypad.
The following options are available:
Options
Set to 00000000 Configures the K1 byte to 00000000 bit pattern.
Default
Description
Not used, Bit pattern 000
Not used, Bit pattern 001
Not used, Bit pattern 010
Not used, Bit pattern 100
Provisioned for Unidirectional switching, Bit
pattern 10
Provisioned for Bidirectional switching, Bit
pattern 101
Multiplex Section Remote Defect Indicator, Bit
pattern 110
Multiplex Section Alarm Indication Signal, Bit
pattern 111. This is the Transmit Illegal button
setting.
Description
Configures the K1 byte to 10101010 bit pattern.
SDH Tab
420