VeEX MPA User Manual page 381

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
2. Select Transmit and choose Set > Set 1.
3. Verify that the Settings Control setting is set to Coupled.
4. Select Interface. The Select Type of Interface menu box appears.
5. Select OC-192 (9953.28 Mbps).
6. Select the Mapping. The Select Mapping menu box appears.
7. Select STS-192c Ethernet WAN.
8. Turn the laser On.
9. Select Receive and choose SIG. Ensure that a valid signal is being received.
10. If any errors or alarms are being received, then resolve the errors or alarms
being detected before continuing.
11. Select the
settings.
Configuring APS (K1 and K2) Commands
The following only applies to SONET and SDH protocol processors.
Automatic Protection Switching (APS) is a function that allows an LTE to switch to a
backup (or protection) channel in case errors or failures occur on the working channel.
APS commands can be configured for either Linear- or Ring-based SONET and SDH
networks and are transmitted using the K1 and K2 bytes of the Line Overhead.
You can test your network's APS response by generating a condition that is likely to
cause APS switching. You also have the capability to generate specific APS messages
and monitor the response by configuring the K1 and K2 bytes.
You can create up to 16 different K1 and K2 byte configurations (known as byte
sequences) to measure and stress your equipment's APS switching capabilities.
To configure K1 and K2 byte values:
1. Select a protocol processor mode.
2. Select the Transmit button.
381
Packet tab
to configure and test the 10G WAN mapping and Streams

Hide quick links: