Error Type
Error Rate
Selects the type of error to transmit into a stream.
The following types may available, depending on the Interface
selected:
Bit Error (Stream #n) - Generates bit errors in the
payload for the specified stream number.
Block - Generates Block errors (only for 10G LAN and
10G WAN)
Code - Generates Line Code errors
FCS - Generates an invalid Frame Check Sequence
IP Checksum - Generates an invalid IP header checksum
Runt - Generates an Undersized frame with a bad CRC
(requires a Runt Size value)
Seq Error (Stream #n) - Generates Sequence errors in
the payload for the specified stream number.
Sync Header - Generates a Sync Header errors
UDP Checksum - Generates a UDP Checksum error type
(only for 400GE)
Selecting an error type will not send the error immediately but
will only select the type of error to be sent when the Send Error
button is pressed or when an Error Rate is selected.
Some of the errors listed above are only available when
Stream traffic is being generated.
Selects the error rate to be transmitted for the selected error
type. Once the error rate is selected, the system begins
transmitting errors.
Select one of the following:
1E-<x> - X is an exponential value from 1 to 10. Selecting
one of these sets the error rate to 1 x 10
exponential the higher the error rate.)
User Defined – Enter the desired error rate in increments
of 0.1. For example, with user defined, error rates are not
limited to 1 x 10
such as 2.6 x 10
-x
but more exact choices are available
-4
-3
or 7.1 x 10
Packet Tab
-x
(The smaller the