MPA_e_manual_D07-00-129P_RevA00
The following options are available from the Results screen:
Error / Alarm
Event Log
Large LED
Graphs
Multi Chan
OTN Results - Error / Alarm
The reported Errors and Alarm are a result of incoming errors/alarms that are generated
by the OTN network, or errors/alarms that are intentionally generated by the system
when it is used in a loopback environment.
The Results Error / Alarm screen contains the following screens:
Scan - Select Scan to access a quick summary of incoming errors and alarms. It
is effective in identifying a general area to investigate when error or alarm activity
is detected. This function displays a list of received errors and alarms. For
alarms, the duration is reported as a count in seconds. For errors, an error count
is reported.
When no activity is occurring, the screen displays "No OTN Errors or Alarms"
Errors - The unit can monitor and report errors on the incoming OTN signal. The
Errors function provides a detailed analysis of the incoming error as described
below.
The following OTN errors can be monitored:
FRAME
MFAS
FEC:Uncorrected
FEC:Corrected
OTU:BIP8
ODU:BEI
OPU:OMFI
OPU:Cm CRC8
TCM1:BIP8 - TCM6:BIP8
TCM1:BEI - TCM6:BEI