MPA_e_manual_D07-00-129P_RevA00
Protocol Tabs
BW Ceiling
BW Floor
Automated Test
Sequence
The following list of tasks demonstrate how to configure and test each of the RFC-
2544 benchmark tests.
•
To Configure the RFC-2544 test settings see
•
To run an RFC-2544 Thru Put test see
•
To run an RFC-2544 Frame Loss test see
•
To run an RFC-2544 B2B Burst test see
RFC Tests - Graph
On completion of the RFC 2544 testing, the Throughput and Frame Loss test results
can be graphically displayed.
709
Sets the high-end of the bandwidth test range. The RFC test
will not exceed the setting. Valid values are 0.10 – 100.
IMPORTANT: The minimum delta between the ceiling and
floor setting is 1. For example, if the BW Floor is set to 9, then
the BW Ceiling must be set to 10, or greater.
Sets the low-end of the bandwidth test range. The RFC test
will not exceed the setting. Valid values are .01 – 99.
IMPORTANT: The minimum delta between the ceiling and
floor setting is 1. For example, if the BW Ceiling is set to 10,
then the BW Floor must be set to 9, or lower.
The following parameters allow the user to configure and test
each of the RFC tests, so that one will run after the previous
test completes.
•
Thruput/Latency checkbox and status field
•
Frame Loss checkbox and status field
•
B2B Burst checkbox and status field
•
Start/Stop Button
•
Test Status field
What are RFC 2544 Tests?
Throughput Testing
Frame Loss Testing
Back-to-Back Burst Testing