MPA_e_manual_D07-00-129P_RevA00
Enable/Disable
check boxes
Packet Sizes
BW Ceiling
BW Floor
Automated Test
Sequence
The following list of tasks demonstrate how to configure and test each of the RFC-
2544 benchmark tests.
To Configure the RFC-2544 test settings see
To run an RFC-2544 Thru Put test see
To run an RFC-2544 Frame Loss test see
RFC Tests - Through Put Test (Thru Put)
Allows the user to select the packet sizes that will be used for
the RFC tests.
Displays the packet sizes. Selecting a Packet Size button
allows the user to assign a user-defined frame size to the
packet.
Valid value ranges are 68 - 2148.
Sets the high-end of the bandwidth test range. The RFC test
will not exceed the setting. Valid values are 0.10 – 100.
IMPORTANT: The minimum delta between the ceiling and
floor setting is 1. For example, if the BW Floor is set to 9, then
the BW Ceiling must be set to 10, or greater.
Sets the low-end of the bandwidth test range. The RFC test
will not exceed the setting. Valid values are .01 – 99.
IMPORTANT: The minimum delta between the ceiling and
floor setting is 1. For example, if the BW Ceiling is set to 10,
then the BW Floor must be set to 9, or lower.
The following parameters allow the user to configure and test
each of the RFC tests, so that one will run after the previous
test completes.
Thruput/Latency checkbox and status field
Frame Loss checkbox and status field
Start/Stop Button
Test Status field
What are RFC 2544 Tests?
Throughput Testing
Frame Loss Testing
Packet Tab
650