VeEX MPA User Manual page 324

Multi-protocol analyzer
Table of Contents

Advertisement

MPA_e_manual_D07-00-129P_RevA00
Expected VT
Signal Label
TIM Alarm
Reporting
Select one of the following values for the expected VT Signal
Label:
The following options are available:
00 (Unequipped)
01 (Equipped)
02 (Asynchronous)
03 (Bit Synchronous)
04 (Byte Synchronous)
(05) ATM
06 (O.181 Test Signal Mapping)
07 (VC-AIS)
User Defined - Any 3-bit value 0h to 7h
This option is only available for VT-1.5, VT-2, and VT-6
mappings.
Enables or Disables Trace Identifier Mismatch (TIM) alarm
reporting.
A Section Trace Identifier Mismatch (TIM-S) alarm
occurs when the incoming J0 trace does not match the
Expected J0 trace setting, as defined below.
An STS Path Trace Identifier Mismatch (TIM-P) alarm
occurs when the incoming J1 trace does not match the
Expected J1 trace setting, as defined below.
A TCM Trace Identifier Mismatch (TC-TIM-P) alarm
occurs when the incoming TC trace does not match
the Expected TC Trace setting, as defined below, and
when TC Error/Alarm Processing is Enabled.
When Disabled, all TIM alarms are ignored.
SONET Tab
324