Check & Adjust,
Results
22.7.7
Access
Check & Adjust
Settings - TS instrument
IF
no more runs must be added
Key
Description
Back
To return to the previous panel.
Redo
To reject all results and to repeat the complete check and
adjust procedure.
Finish
To accept and record the new determined instrument errors.
If the report sheet recording has been enabled, then the
results are written and appended to an existing report sheet.
Description of metadata
Metadata
Option
New
Display only
Old
Display only

Viewing the Current Values

In Check & Adjust, What do you want to do? select View the current val-
ues and press Next.
Key
Description
OK
To return to Check & Adjust, What do you want to do?.
More
To display information about the date of the determination,
the standard deviation of the errors and the temperature
during the determination.
The temperature of the environment around the instrument can differ from the
temperature shown on the panel as it is the internal temperature of the instru-
ment.
THEN
select Finish the calibration &
store the results and press Next to
accept the measurements and to
access the results panel.
Description
The new determined and averaged instru-
ment errors.
The old instrument errors, which are currently
valid on the instrument.
275