Field
Measure
point every
When dis-
tance
changed by
Or when
height
changed by
Minimum
distance
between
points
Stop time
Store points
Logging
starts when
932
Option
Description
Available unless Measure new point after
certain: Distance or height, Measure new
point after certain: Distance & time or
Measure new point after certain: Key
press.
Editable field
For Measure new point after certain: Dis-
tance and Measure new point after cer-
tain: Difference in height. The difference
in distance or height before the next auto
point is logged.
From 0.1 sec
For Measure new point after cer-
to 60.0 sec
tain: Time. The time interval before the next
auto point is logged.
For GS08plus logging rates of 0.2 s and
slower are supported.
Editable field
Available for Measure new point after cer-
tain: Distance or height. The value for the
difference in distance before the next auto
point is logged.
Editable field
Available for Measure new point after cer-
tain: Distance or height. The value for the
height difference before the next auto point
is logged.
Editable field
Available for Measure new point after cer-
tain: Distance & time. The distance within
which the position is considered stationary.
Editable field
Available for Measure new point after cer-
tain: Distance & time. The time while the
position must be stationary until an auto
point is stored.
Available for GS.
To MDB (pts
Logs auto point to a job file. Point logging at
only)
up to 20 Hz. Coding and logging of offset
points is not possible. Points cannot be dis-
played in 3D viewer or output using format
files.
To DBX
Logs auto points to the DBX. Point logging at
(pts&codes)
up to 1 Hz. Coding and logging of offset
points is possible. Points can be displayed in
3D viewer or output using format files.
Available for GS.
Accessing
Logging of auto points starts immediately
the Measure
when the Measure app is accessed.
app
Changing this setting while auto
points are being logged stops the
logging. It must then be restarted.
Measure - Auto Points