47.4
47.4.1
Availability
Access
Roads - Tunnel
Key
Description
OK
To store the defined scan segment and return to Scan Seg-
ments.
Distance
To measure the distance to points at the starting angle and
the end angle of a segment. When Start angle or End
angle is highlighted, set the verticle circle values by aiming
the telescope at the relevant point and press Distance.
Position
To review the position of the segment once it has been
defined. The instrument turns to the corresponding angle.
Available when Start angle or End angle is highlighted.
Description of fields
Field
Option
Segment
Editable field
name
Start angle
Display only
End angle
Display only
Scan this
Check box
segment
Scan inter-
Editable field
val
If overlapping segments are defined, then a non-scan segment has
priority over a scan segment.
The Toolbox

Profile Viewer

This menu function is available for the check method Scan profile.
This menu option is always available. The data that can be viewed depends on
those data available in the job. It is independent of the currently measured
Scan Profile points.
The measured profiles to be viewed must be saved in the job.
1.
Press Fn Tools in Stake Face.
2.
Select Profile Viewer in Stake Face Tools.
Description
The name of the scan segment.
The angle measured to the point at the
beginning of the segment.
Highlight this field, aim at the start of the
segment and press Distance to see the
angle value in this field.
The angle measured to the point at the end
of the segment.
Highlight this field, aim at the end of the
segment and press Distance to see the
angle value in this field.
When this box is checked, the segment is
scanned.
When this box is not checked, the segment is
not scanned.
Defines how often a point is measured in
this segment of the profile.