53.2
Description
Access

Over Last Setup

Last used base point
920
To edit a point, open the selectable list for Point ID and press Edit.
Key
Description
Next
To accept changes and access the subsequent panel.
Coord
To view other coordinate types. Local coordinates are availa-
ble when a local coordinate system is active.
Back
To return to the previous panel.
Next step
Next to access Base setup complete.. Follow the instructions on the panel.
Over last setup
To use the same coordinates as when the instrument was last used as a base.
Availability:
The instrument has been used as base before. No point in the design job has
the same point ID as the last used point.
After turning off, the base coordinates are stored in the System RAM. They can
be used again the next time the instrument is used as a base. This functional-
ity means that even if the data storage device that previously contained the
base coordinates is formatted, the last used coordinates can still be used.
Select Leica Captivate - Base: Base setup\Over last setup.
This panel is identical with the one in Over known point. Refer to "53.1 Over
known point".
Next step
Next to access Last used base point.
The point ID and coordinates of the last used base are displayed in grid. When
no local coordinate system is active, WGS 1984 coordinates are displayed.
Refer to "53.1 Over known point" for information on the keys.
Leica Captivate - Base - Start base