Leica Captivate Technical Reference Manual page 305

Table of Contents

Advertisement

25.4
Description
Settings - Point storage
Field
Option
Positions
Editable field
Position
Display only
update
Number of
Editable field
positions
Baseline
Selectable list
length
Next step
OK closes the panel.
TS offsets & checks
Offsets
The offset values are applied to measured points. The Offset function allows
offset points to be determined, for instance when the reflector cannot be set
up directly on a point. Transverse, longitudinal and/or elevation offsets can be
defined from the reflector position to the offset point. All the displayed and
recorded measurement data is in relation to the offset point.
Repeat measurement checks
The instrument can be configured to monitor sequentially stored measure-
ments and to notify the user if the coordinates lie within a defined range of
each other.
If configured, the X,Y coordinates of a point being stored can be compared to
the coordinates of the last previously stored point. If the difference is less than
the defined position tolerance then a warning is shown. It can now be decided
whether to store the point or not.
If configured, backsight target points and resection target points which were
measured during the setup procedure are then also checked in this manner.
Description
Raw data is logged for a minimum number of
positions even when the Position quality
better than and Height quality better
than is already less than the specified maxi-
mum.
Displays the value for GS position update
rate as configured in Screen, Audio & Text
Input, Screen page.
Sets the number the positions which must
be observed before the instrument stops
measuring. Counting the number of posi-
tions starts when Measure is pressed.
Used for the calculation of the occupation
time for Stop measurement based
on: Stop & go indicator.