Parameters for Auto
Stop
Settings - Point storage
The parameters shown on this panel depend on the setting for Stop measure-
ment based on.
Key
Description
OK
To accept changes.
Description of fields
Field
Option
Time at
Editable
point
fields
Number of
Editable
obs
fields
At logging
Display only
rate
8+ satellites
Editable field
for, 7 satel-
lites for, 6
satellites
for, 5 satel-
lites for and
4 satellites
for
Baseline
Selectable list
length
Extend
From 1.0 to
occupation
5.0
time by fac-
tor of
Next step
1.
OK closes the panel.
Description
Sets the required observation time for each
point. Counting time starts when Measure is
pressed. The instrument stops measuring
when the set length of time is reached.
Sets the required number of observations
that are to be recorded at each point. Count-
ing observations starts when Measure is
pressed. The instrument stops measuring
when the set number of observations is
reached.
Displays the rate at which static raw observa-
tions are logged as configured.
Sets the required observation time depend-
ing on the number of satellites available.
Counting time starts when Measure is
pressed. The instrument stops measuring
when the set length of time for a certain
number of satellites is reached.
Should the number of available satellites
change during observation, the observations
already recorded are taken into account.
Used for the calculation of the occupation
time for Stop measurement based
on: Stop & go indicator.
The factor extends the point occupation time
recommended by the software. It directly
influences the occupation time shown in
Time at point in Measure.