PowerSearch window

Dynamic PowerSearch
window

Direction of search

33.3
Description
394
The PowerSearch filter can be switched on and switched off in the Aim &
Search icon pop-up bubble.
After clicking the Filter off bubble icon, the filter is deactivated, but not
deleted. The filter can be switched on again using Filter on.
When no filter is learned, the bubble icons Filter on and Filter off are not
shown.
When pressing the Filter learn bubble icon, the instrument performs a Power-
Search scan. The scan order is:
400 gon PowerSearch rotation around Hz with a V angle of 100 gon
400 gon PowerSearch rotation around Hz with a V angle of 60 gon
400 gon PowerSearch rotation around Hz with a V angle of 140 gon
When learning the filter, a previous filter is deleted.
When measuring new points for a setup, the current filter is updated.
The PowerSearch filter is reset after a new setup.
The PowerSearch filter is kept when shutting down and restarting the instru-
ment.
The PowerSearch window can be defined individually. It is specified by absolute
angle values and does not change its position. The PowerSearch window can
be set in the Target Search, PowerSearch window page by aiming at two
opposite points of the PowerSearch window. When Use PowerSearch win-
dow is checked and a PowerSearch is started, a prism is searched for within
the defined window.
When Use PowerSearch window is not checked and the instrument has lost
lock, after the prediction time, the prism is searched for in a dynamic Power-
Search window. This window covers a region at the position after prediction of
horizontal 100 gon by vertical 40 gon.
The PowerSearch routine can be activated clockwise or anticlockwise by using
hotkeys. This action will have no influence on the prism search settings.

Follow Moving Prisms - Lock

Lock enables instruments equipped with automatic aiming to follow a moving
prism. The automatic aiming sensor is active when Lock is active. When Target
lock on is selected in the icon bar, an automatic aiming search is executed.
The instrument locks onto the prism and follows its movements. Automatic
aiming offsets are continuously applied to the angle measurements. When the
instrument loses lock to the prism, a PowerSearch or fine search (auto aiming
search) can be executed depending on the prism search settings.
Lock is unavailable for SmartStation.